| 40kvA/120kv Frequency Series-Parallel Resonance Dari Electric recommends for you Device Features 1) Automatically find the resonance point, frequency range 20-300Hz, frequency resolution 0.1Hz; 2) Automatic voltage withstand test, users can set test procedures, the system automatically completes the test process according to the set procedures; 3) Automatically save test data, data query function, query previous test data according to query conditions; 4) Five protection functions: overvoltage, overcurrent, power failure, flashover and full voltage output protection; n Overvoltage protection: overvoltage protection value can be manually set; when the output voltage of the whole device reaches the protection setting value, the whole device is automatically cut off; n Overcurrent protection: overcurrent protection value can be manually set; when the output current of the whole device reaches the protection setting value, the whole device is automatically cut off; n Breakdown protection: with discharge or flashover protection function, when a ground flashover occurs on the high-voltage side, the whole device is automatically cut off. It will not cause injury to test equipment and personnel, and the electronic components in the variable frequency power supply will not be broken down; 害,变频电源内电子元件不会击穿; n Power failure protection: after the test power supply is cut off, the device can protect quickly; n Full voltage output protection: during the voltage regulation process, it is strictly guaranteed that the variable frequency power supply will not output full voltage; 5) The LCD screen can display the power supply voltage and current; the frequency, voltage, and current of the high-voltage output; Scope of Application 1. Meet the requirements of 15000kW/6kV thermal power generator, test frequency 45~65Hz, capacitance ≤0.1μF, maximum test voltage not exceeding 16kV. 2. Meet the variable frequency AC withstand voltage test of 6.3kV/185mm2 length ≤300m cable, capacitance ≤0.12μF, test frequency 30~300Hz, test voltage 15kV. 3. Meet the AC withstand voltage of 1250kVA/6kV main transformer, test frequency 45~65Hz, capacitance ≤0.01μF, maximum test voltage not exceeding 25kV. 4. Meet the AC withstand voltage of 6kV busbars, switches and other electrical equipment, test frequency 30~300Hz, maximum test voltage not exceeding 32kV. Technical Parameters of Component Devices 1. Excitation Transformer MSB-4.5kVA/1kV/3kV0.4kV 1 unit a) Rated capacity: 4.5kVA; b) Input voltage: 380V, single phase; c) Output voltage: 1kV; 3kV; d) Structure: dry type; e) Weight: about 30 kg; 2. Variable Frequency Power Supply MSBPB-4.5kW/380V 1 unit a) Rated output capacity: 4.5kW b) Working power supply: 380±10%V (single phase), power frequency c) Output voltage: 0 – 400V, single phase, d) Rated input current: 12A e) Rated output current: 12A f) Output waveform: sine wave g) Voltage resolution: 0.01kV h) Voltage measurement accuracy: 0.5% i) Frequency adjustment range: 30 – 300Hz j) Frequency adjustment resolution: ≤0.1Hz k) Frequency stability: 0.1% l) Running time: meet the test requirements of the test object m) Meet the test requirements of the test object, maximum component temperature ≤65K; n) Noise level: ≤50Db o) Weight about 15kg; 3. High Voltage Reactor MSDK-30kVA/20kV 2 sections a) Rated capacity: 30kVA; b) Rated voltage: 20kV; c) Rated current: 1.5A; d) Inductance: 45H/single section; two sections in series 90H e) Quality factor: Q≥30 (f=45Hz); f) Structure: dry type; g) Weight: about 32kg; 4. Capacitive Voltage Divider FRC-40kV -500pF 1 set a) Rated voltage: 40kV; b) High voltage capacitance |