全自动Dielectric Loss Tester-扬州达瑞

Automatic Comprehensive Transformer Characteristics Tester - Yangzhou Ruida

Published: 2020-08-03 11:10:43

Views: 2922

Category: CT/PT Characteristic Tester

Product Description
Automatic Comprehensive Transformer Characteristics Tester

  Darui Electric recommends for you  

The Automatic Comprehensive Transformer Characteristics Tester is a multifunctional on-site testing instrument specifically designed to test transformers for parameters such as volt-ampere characteristics, transformation ratio, polarity, secondary winding resistance, burden, phase angle error, and ratio error. This transformer tester is based on the frequency conversion method to test CT/PT volt-ampere characteristic curves and 10% error curves, outputting only 180V AC voltage and 12A AC current, yet it can handle CT testing with knee point voltages up to 30kV.

   Functional Features

1. This transformer tester can perform testing and calculations on CT and PT in accordance with various standards such as GB1208-2006 (IEC60044-1), GB16847-1997 (IEC60044-6), and others.

2. It uses the frequency conversion method to test CT/PT volt-ampere characteristic curves and 10% error curves, outputting only 180V AC voltage and 12A AC current, capable of handling CT testing with knee point voltages up to 30kV.

3. Comprehensive functionality, suitable for testing steady-state or transient characteristics of various types of CTs and PTs, including excitation, transformation ratio, phase, polarity, secondary winding resistance, burden, ratio error, and phase angle error.

4. Automatically provides parameters such as knee point voltage/current, 10% error curve, 5% error curve, accuracy limit factor (ALF), instrument security factor (FS), secondary time constant (Ts), remanence coefficient (Kr), accuracy class, saturated and unsaturated inductance, etc.

5. The instrument features a user-friendly and aesthetically pleasing interface, with a full Chinese graphical interface and a 5.7-inch graphic transflective LCD, visible in sunlight.

6. The instrument is operated using a rotating optical mouse, making operation simple, quick, and easy to master.

7. The device can store test data, which is not lost upon power failure.

8. The panel comes with a built-in printer that can automatically print generated test reports.

9. Testing is very convenient; except for burden testing, all other tests are based on the same wiring.

10. The device is portable, weighing less than 9kg.

   Test Functions

1. Excitation characteristic test.

2. Transformation ratio test.

3. Phase and polarity test.

4. Measurement of ratio error and phase angle error for various primary currents and various burdens of CT.

5. Measurement of CT secondary winding resistance.

6. Measurement of CT secondary circuit burden.

7. Testing and analysis of CT transient characteristics.

8. Measurement and verification of various types of CTs and PTs, including protection CTs, metering CTs, TP-class transient CTs, CTs with excitation saturation voltage up to 30kV, transformer bushing CTs, and PTs of various voltage levels.

9. Measurement of CT and PT parameters such as knee point voltage/current, 10% (5%) error curves, accuracy limit factor, instrument security factor, secondary time constant, remanence coefficient, accuracy class, saturated and unsaturated inductance, etc.

   Technical Parameters

1. Power supply: AC 220V±20%, 50Hz

2. Output voltage: 0~180V (RMS) 

3. Output current: 0~12A (RMS), peak 36A

4. CT transformation ratio measurement range: 1~30000

5. PT transformation ratio measurement range: 1~30000

6. Voltage measurement: accuracy: ±0.2%

7. Transformation ratio measurement: accuracy: ±0.2%

8. Phase measurement: accuracy: ±5’, resolution: 0.5’

9. Secondary winding resistance measurement range: 0~300Ω, resolution: 0.2mΩ, accuracy: 0.5%±2mΩ

10. AC burden measurement: 0~300VA, accuracy: 0.5%±0.02VA

11. Operating conditions: temperature: -10℃~50℃, humidity: ≤90%

The Automatic Comprehensive Transformer Characteristics Tester is a multifunctional on-site testing instrument specifically designed to test transformers for parameters such as volt-ampere characteristics, transformation ratio, polarity, secondary winding resistance, burden, phase angle error, and ratio error. This transformer tester is based on the frequency conversion method to test CT/PT volt-ampere characteristic curves and 10% error curves, outputting only 180V AC voltage and 12A AC current, yet it can handle CT testing with knee point voltages up to 30kV.

Note: The above information and technical parameters are compiled and published by Yangzhou Darui Electric Co., Ltd.



 
WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us