Structural features of mining cable fault detector:
1. The GHKLC mining type consists of a control part (low voltage) and high-voltage rectification, discharge, and inspection parts. Safe spaces are reserved between high and low voltage, and between high/low voltage and the casing.
2. To ensure the safety of equipment and personnel, high voltage initiation must be operated by a designated person with a key.
3. Each fault detection or cable inspection ensures that high voltage starts from zero and ramps up, with high and low voltage limit states. The voltage increase or decrease process is controlled by buttons, with smooth voltage change rates, making operation safe and simple.
4. The DC withstand voltage test time can be automatically controlled by a digital timer (or manually controlled), ensuring accurate and reliable test time.
5. Leakage current can be measured at any time as needed during the withstand voltage test process.
6. The equipment has overcurrent and short-circuit protection, with pre-start warning and overcurrent protection.
7. The control panel is equipped with power switch, high voltage start, high voltage interruption, voltage increase, voltage decrease switches or buttons, and a digital timer relay for withstand voltage test time.
8. The display panel has meters for high voltage, leakage current, and low voltage total current, with indicator lights for power, high voltage, timing, and a window for observing sphere gap discharge.
9. A dedicated high-voltage discharge rod is provided for discharging after each fault detection or test to ensure safety, with a grounding symbol at the bottom of the box.
Technical parameters for mining type:
1. Instrument operating voltage: AC220V 50Hz
2. Fault detection DC output: 0—15KV
3. Cable fault detection accuracy: ±50mm
4. Test output voltage: 0—30KV
5. High-voltage energy storage capacitor: 1.4μf/12KV,
6. AC output voltage: 0—22KV
7. Withstand voltage test time: 0—30s (adjustable)
8. Leakage current test: 0—300μA
9. High-voltage transformer capacity: 4KVA
10. Discharge sphere adjustment distance: 0—10mm
11. Dimensions: 900×850×1200
Product Introduction of Mining Cable Fault Detector:
Mining cable fault detector: Coal mines are major users of cables. This device is based on the partial discharge method that does not damage the original layout of the cable, accurately detects the damaged part of the cable, and also has the function of testing after repair. Therefore, it is a reliable testing instrument for cable repair in coal mines. Coal mines are major users of cables. Due to the harsh underground working conditions, the annual damage of various cables is relatively large. To save costs and reduce production costs, each mine generally has its own cable repair team. However, due to the limitations of testing equipment and processes, fault detection and testing of repaired cables such as fully mechanized mining cables often do not meet expectations, and most use the forced breakdown method that causes significant damage to cable insulation. Based on the advantages of various testing instruments and the requirements for mining cables, our company has specially designed and manufactured a new generation of mining cable tester.
Cable Fault Detector
Coal mines are major users of cables. Due to the very harsh underground working conditions, the annual damage of various cables is relatively large. To save costs and reduce costs, each coal mine generally has its own cable repair team. Due to harsh testing conditions and equipment limitations, fault detection and testing of mining cables often do not meet expectations. Based on the advantages of various testing instruments and the requirements for mining cables, our company has specially designed and manufactured a new generation of mining cable tester.
Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd.