| Automatic Anti-Interference Precision Dielectric Loss Tester Recommended by Darui Electric Technical Parameters 1. Measurement Accuracy: Cx: ±(reading × 1% + 1pF) tgδ: ±(reading × 1% + 0.00040) 2. Anti-Interference Index: Frequency conversion anti-interference, can still achieve the above accuracy under 200% interference 3. Capacitance Range: Internal high voltage: 3pF~60000pF/10kV 60pF~1μF/0.5kV External high voltage: 3pF~1.5μF/10kV 60pF~30μF/0.5kV Resolution: 0.001pF, 4 significant digits 4. tgδ Range: Unlimited, resolution 0.001%, automatic identification of capacitor, inductor, and resistor test objects 5. Test Current Range: 10μA~5A 6. Internal High Voltage: Set voltage range: 0.5~10kV Output current: 200mA Voltage adjustment method: continuous smooth adjustment Voltage accuracy: ±(1.5% × reading + 10V) Voltage resolution: 1V Test frequency: 45, 50, 55, 60, 65Hz single frequency 45/55Hz, 55/65Hz, 47.5/52.5Hz automatic dual frequency conversion Frequency accuracy: ±0.01Hz 7. External High Voltage: Test current 1A for normal wiring, power frequency or variable frequency 40-70Hz Test current 10kV/1A for reverse wiring, power frequency or variable frequency 40-70Hz 8. CVT Self-Excitation Method Low Voltage Output: Output voltage 3~50V, output current 3~30A 9. Measurement Time: About 40s, depending on measurement method 10. Input Power: 180V~270VAC, 50Hz/60Hz±1%, mains or generator power supply 11. Ambient Temperature: -10℃~50℃ 12. Relative Humidity: <90% Product Overview Dielectric loss measurement is a very basic method in insulation testing, which can effectively detect overall moisture, deterioration, and local defects in electrical equipment insulation. It is widely used in electrical manufacturing, electrical equipment installation, handover, and preventive tests. The measurement of dielectric loss in transformers, transformers, reactors, capacitors, bushings, and arresters is a basic method to evaluate their insulation performance. The automatic anti-interference precision dielectric loss tester breaks through the traditional bridge measurement method, adopts variable frequency power supply technology, uses single-chip microcomputer and modern electronic technology for automatic frequency conversion, A/D conversion, and data calculation; it has strong anti-interference ability, fast test speed, high accuracy, fully automatic digitalization, and simple operation; the power supply uses a high-power switching power supply with automatic voltage boosting; it automatically filters out 50Hz interference, suitable for on-site testing in environments with strong electromagnetic interference such as substations. It is widely used for dielectric loss measurement of transformers, transformers, bushings, capacitors, arresters, and other equipment in the power industry. Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd. |