| Containerized Load Bank Darui Electric recommends Marine containerized load banks (ultra-high-power intelligent load banks) typically use diesel fuel for marine generators. When diesel engines operate below 50% load or remain unloaded for extended periods, incomplete combustion, carbon buildup, and reduced overall efficiency can occur, eventually leading to starting difficulties, insufficient power, increased fuel consumption, and premature overhaul or scrapping. Load banks serve as ideal artificial loads for generators. The ALB-DT marine containerized load bank (ultra-high-power intelligent load bank) is an ideal testing device for measuring parameters such as generator power, frequency, voltage, current, power factor, and stability. The ALB-D intelligent three-phase AC load bank (diesel generator set test load bank) we provide can test the output power and load-bearing capacity of various generator sets. Function Introduction: 1. Stainless steel fixed container design. 2. During acceptance of newly installed diesel generators, verify whether they meet design requirements. 3. After adding noise reduction equipment such as silencers to diesel generators, test whether their output power meets the operational needs of communication equipment. 4. After diesel generator repair, test whether performance indicators such as output power and load capacity meet requirements. 5. Routine maintenance and periodic testing of diesel generators: according to newly issued communication power supply maintenance regulations, load testing should be conducted for 15-30 minutes every six months. Application Fields: Load testing for ships, railways, electric power, and communication base station power supplies. Main Technical Specifications Discharge Power 10KW 20KW 20KW 20KW 20KW Discharge Voltage Range AC 400V/20V Three-phase four-wire AC 400V/230V Three-phase four-wire AC 300V Three-phase four-wire AC 600V Three-phase four-wire AC 10.5KV Three-phase four-wire Frequency Measurement Range 50HZ/60HZ 50HZ/60HZ 50HZ 50HZ 50HZ Power Measurement Range 0-10kw 0-20kw 0-100kw 0-500kw 0-10kw Adjustment Accuracy 1KW 0-20kw 1KW 1KW 1KW Control Form AC Contactor AC Contactor High-voltage Vacuum Contactor High-voltage Vacuum Contactor High-voltage Vacuum Contactor Power Supply Three-phase + N AC 380V Three-phase + N AC 380V Three-phase + N AC 380V Three-phase + N AC 380V Three-phase + N AC 380V Protection Devices Overvoltage, high-temperature alarm, fan fault protection Overvoltage, high-temperature alarm, fan fault protection Overvoltage, high-temperature alarm, fan fault protection Overvoltage, high-temperature alarm, fan fault protection Overvoltage, high-temperature alarm, fan fault protection Cooling Method Forced air cooling Forced air cooling Forced air cooling Forced air cooling Forced air cooling Optional Functions Manual type / Computer remote control Voltage ±(0.25% reading + 0.25% range) ±(0.25% reading + 0.25% range) Optional meter Optional meter Optional meter Current ±(0.25% reading + 0.25% range) ±(0.25% reading + 0.25% range) Power Power factor = 1.0: ±(0.25% reading + 0.25% range) Power factor = 1.0: ±(0.25% reading + 0.25% range) Running Time ±2 seconds per hour ±2 seconds per hour Energy Power factor = 1.0: ±(0.25% reading + 0.25% range) Power factor = 0.5: ±(0.5% reading + 0.5% range) Power factor = 1.0: ±(0.25% reading + 0.25% range) Power factor = 0.5: ±(0.5% reading + 0.5% range) Note: The above information and technical parameters are compiled and released by Yangzhou Darui Electric Co., Ltd. |