全自动Dielectric Loss Tester-扬州达瑞

Data Center Rack-Mounted Load - Yangzhou Darui

Published: 2020-08-10 14:23:23

Views: 2922

Category: Partial Discharge Tester

Product Description



Data Center Rack-Mounted Load

Darui Electric recommends

It is well known that when servers are placed in an environment with poor heat dissipation, the lifespan of hard drives is greatly reduced, and other components of the server may also fail successively. Modern server motherboards typically limit the CPU frequency when they detect CPU overheating, so even if the server is not completely damaged, it may reach a level of unusability. Sometimes, component overheating can also lead to process crashes.

The data center rack-mounted load box is mainly a purely resistive load that simulates the heat generation of data servers and the loading conditions of circuits. It can serve as a heat source similar to rack-mounted servers to simulate and test the capability of the data center's cooling system and whether air flow is controllable. It can also test AC power sources such as UPS power supplies and backup generator sets. With step-by-step segmented power free combination control, it realistically reproduces the energy consumption and heat dissipation of data server IT equipment. By using the data center rack-mounted load box to test the voltage stability under load in the data center, it ensures the effective operation of the power supply system, data service system, and others.

The data center rack-mounted load box can control the gear positions under rated voltage to obtain different current levels and on/off times to meet customer usage requirements. The power control panel of the load box can control the action of circuit breakers, and the main circuit of the circuit breakers controls the on/off of the resistive load units. It also has temperature detection and protection functions; when the load temperature exceeds the safety threshold, it automatically unloads and alarms. The site is equipped with electrical parameter monitoring instruments that can monitor all electrical parameters of servers, UPS, generator sets, etc., in real time, and automatically generate various charts, curves, and test reports for a more intuitive understanding of equipment usage.

► Technical Parameters

Model LB-1KW-380VAC
Rated Power 1KW
Test Voltage, Frequency Three-phase 380VAC/50Hz
Control Voltage Single-phase 220VAC /50Hz
Power Factor 1
Load Characteristics Purely resistive
Load Control Circuit breaker control
Communication Interface RS232, 485 communication
Loading Accuracy ±5%
Cooling Method Forced air cooling, front intake, rear exhaust
Protection Level IP20 (indoor environment)
Insulation Level F, with grounding bolt at the bottom of the chassis
Monitoring Function Monitor current and voltage parameters of the test circuit
Dimensions 430*177*500mm
Measurement and Control Method The box terminal is equipped with a multifunctional display meter, located inside the box, which can monitor electrical parameter data
Load Protection

1. Emergency Stop: Manual one-key forced unloading; loading is not possible when the emergency stop is locked

2. Temperature Protection: When the load temperature exceeds the safety threshold, it automatically unloads and alarms



Note: The above information and technical parameters are compiled and published by Yangzhou Darui Electric Co., Ltd.



WeChat QR Code
💬
💬 Message ✕

Hello! Have you found what you need? Contact us directly online!

Leave a Message for Consultation
Yangzhou Darui Electric Co., Ltd.
主营产品:Dielectric Loss Tester、Transformer Ratio测试仪、Loop Resistance Tester、高压None线核相仪、Insulation Resistance Tester、Partial Discharge Tester、Cable Fault Tester、DC Resistance Tester等。
☎ Phone: 18952707000(关经理)📞 Landline: 0514-88770377✉ Email: 195214804@qq.com
Verification Code
By submitting, you agree to ourTerms of ServiceandPrivacy Policy
🏠 网站Home📞 一键拨号✉ Contact Us